Fibre optic connection, Alarm connection (9-position screw terminal) – Westermo LD-64 User Manual

Page 20

Advertising
background image

20

6073-2002

Fibre optic connection

LD-64

RX1

RX2

TX2

TX1

RX1

RX2

TX2

TX1

LD-64

LD-64

RX1

RX2

TX2

TX1

RS-422/485

RS-232

or

RS-422/485

RS-232

or

RS-422/485

RS-232

or

Note! Always connect channel 1 to channel 2

1

2

3

4

5

6

7

8

9

Alarm indication

Alarm connectors are polarity depended.

Alarm signals
Upon failure the circuit between the contacts “C” and
“E” is closed. This circuit can be used to generate an
external alarm signal by connecting an external relay as
shown on page 21. Please note that the maximum
allowed voltage/current is 30 V/80 mA.

Alarm connection
(9-position screw terminal)

Connection

Description

Polarity

1

CH2, E

2

CH2, C

+

3

CH1, E

4

CH1, C

+

Note

!

C

E