Westermo Lynx-x06-S2 User Manual

Page 10

Advertising
background image

10

6643-2240

RS-232/422/485
Electrical specification

Configurable for EIA RS-232 or EIA RS-422/485

Data rate

RS-232

50 bit/s – 115.2 kbit/s

RS-422/485 50 bit/s – 2 Mbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set)

Circuit type

TNV-1

Transmission range

RS-232

15 m / 49 ft

RS-422/485 Up to 1200 m / 0.74 mi, depending on data rate and cable

type

Isolation to

All other

Connection

RS-232

RJ-45 according to EIA-561

RS-422/485 RJ-45

Shielded cable

RS-232

Recommended

RS-422/485 Not required, but recommended in railway installations close

to the rails.*

Conductive housing

Yes

Number of ports

1

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.

I/O / Relay output
Maximum voltage/current

60 VDC / 80 mA

Contact resistance

Max 30 Ω

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

I/O / Digital input

Maximum voltage/load current

60 VDC / 2 mA

Voltage levels

Logic one: >12V
Logic zero: <1V

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Advertising