15

6605-2001

Designation Description

PWR

Power supply OK

RD0

RD signal channel 0

TD0

TD signal channel 0

L1

RTS signal channel 0

L2

L3

CTS signal channel 3

L4

L5

RD signal channel 3

L6

TD signal channel 3

L7

RTS signal channel 3

L8

Connections MD-54

Direction

Connection

CCIT V.11

no.

Description

Receiver

1

A’ (R+)

Receiver

2

B’ (R–)

Transmitter

3

A (T+)

Transmitter

4

B (T–)

5

Shield

Connection channel 0, RS-422/485

LED’s description

Direction

Connection

CCITT V.24

Signal description

DCE

9-pos D-sub

Description

O

2

104

RD/Received Data

I

3

103

TD/Transmitted Data

5

102

SG/Signal Ground

I

7

105

RTS/Request To Send

O

8

106

CTS/Clear To Send

I = Input MD-54

O = Output MD-54

Connection channel 0, RS-232/V.24

Direction

Connection

CCITT V.24

Signal description

DCE

no.

Description

I

1

103

TD/Transmitted Data

O

2

104

RD/Received Data

I

3

105

RTS/Request To Send

O

4

106

CTS/Clear To Send

5

102

SG/Signal Ground

I = Input MD-54

O = Output MD-54

Connection channel 3, RS-232/V.24

Digital In, channel 1, 2 and 4 not used.
The definations R+/R–, T+/T– can be various between
different manufactures.