Copyright © 2009 - 2014 Airmar Technology Corp. All rights reserved.

2. Apply sealant to the threads of the remaining screw to prevent

water seeping into the transom.

3. Fasten the stabilizing screw into place with a socket wrench.

For clear access to the screw, remove the transducer assembly
from the bracket (see Figure 4). When reattaching the
transducer, be sure to include the spacer
.

Cable Routing & Connecting

CAUTION: Do not remove the connector to ease cable routing. If
the cable must be cut and spliced, use Airmar’s splash-proof
Junction Box No. 33-035 and follow the instructions provided.
Removing the waterproof connector or cutting the cable, except
when using a water-tight junction box, will void the sensor warranty.

Route the cable over the transom for a detachable installation. For
permanent mounting, route the cable through a drain hole or
through a new hole drilled in the transom above the waterline.

1. If a hole must be drilled through the transom,

choose a location

well above the waterline (see Figure 7). Check for obstructions
such as trim tabs, pumps, or wiring inside the hull. Mark the
location with a pencil. Drill the hole using the appropriate size bit
to

accommodate the connector.

2. Route the cable over or through the transom.
3. On the outside of the hull, secure the cable against the transom

using the cable clamps. Position one cable clamp 30cm (12")
above the bracket. Mark the mounting hole with a pencil.

4. Position the second cable clamp halfway between the first

clamp and the cable hole. Mark this mounting hole.

5. If a hole has been drilled through the transom, open the large

slot in the transom cable cover. Position the cover over the
cable where it enters the hull. Mark the two mounting holes.

6. At each of the marked locations, use a 3mm or 1/8" bit to drill a

hole 10mm (3/8") deep.

7. Apply marine sealant to the threads of the #6 x 1/2" self-tapping

screws to prevent water from seeping into the transom. If you
have drilled a hole through the transom, apply marine sealant to
the space around the cable where it passes through the
transom.

8. Position the two cable clamps and fasten them in place. If used,

push the cable cover over the cable and screw it in place.

9. Route the cable to the instrument being careful not to tear the

cable jacket when passing it through the bulkhead(s) and other
parts of the boat. Use grommet(s) to prevent chafing. To reduce
electrical interference, separate the transducer cable from other
electrical wiring and the engine(s). Coil any excess cable and
secure it in place with cable ties to prevent damage.

10.Refer to your echosounder owner’s manual to connect the

transducer to the instrument.

Checking for Leaks

When the boat is placed in the water, immediately check for
leaks around the screws and any other holes drilled in the hull.
Note that very small leaks may not be readily observed. Do not
leave the boat in the water unchecked for more than three hours.

Maintenance

Anti-fouling Paint

CAUTION: Do not paint the exposed temperature button. Doing
so will slow the sensor’s response time.

Aquatic growth can accumulate rapidly on the transducer’s face
reducing performance within weeks. Surfaces exposed to salt
water that do not interlock must be coated with anti-fouling paint.
Use water-based anti-fouling paint only. Never use ketone-based
paint, since ketones can attack many types of plastic possibly
damaging the transducer. Repaint every 6 months or at the
beginning of each boating season.

Cleaning

CAUTION: Do not use a lubricant on the bracket; grit will stick to
it, increasing friction and wear.

Clean the sensor with a Scotch-Brite® scour pad and mild
household detergent, taking care to avoid making scratches on
the transducer’s face. If the fouling is severe, lightly wet sand with
fine grade wet/dry paper.

Transducer Replacement & Parts

The information needed to order a replacement transducer is printed
on the cable tag. Do not remove this tag. When ordering, specify the
part number, date, and frequency in kHz. For convenient reference,
record this information on the top of page one.
Lost, broken, and worn parts should be replaced immediately.

Bracket Assembly

33-749-01

Obtain parts from your instrument manufacturer or marine dealer.

Gemeco

Tel: 803-693-0777

(USA)

Fax: 803-693-0477
email: [email protected]

Airmar EMEA

Tel: +33.(0)2.23.52.06.48

(Europe, Middle East, Africa) Fax: +33.(0)2.23.52.06.49

email: [email protected]

Figure 7. Cable routing

30cm (12")

cable cover

cable clamp

Copyright © 2009 Airmar Technology Corp.

35 Meadowbrook Drive, Milford, New Hampshire 03055-4613, USA

www.airmar.com

Advertising
This manual is related to the following products: