10.Troubleshooting and Solutions

20

Problem

Possible Causes

Remedies

Diesel engine

won’t start

Not enough fuel

Refill with fuel

Fuel valve is not open

Open the fuel valve

The engine start lever is not
in RUN position

Turn it to the RUN position

Fuel injection pump and
nozzle not delivering fuel, or
not delivering sufficient fuel

Remove the nozzle and
repair it at test table

Low oil

The specified oil level
should be between the
upper level and the lower
level

The nozzle is dirty

Clean the nozzle

The recoil starter is being
pulled with insufficient force

Start the engine according
to the start procedure

The battery is too weak

Charge the battery or
replace it with a new one

The generator

is not

producing

power

AC circuit breaker switch
not turned on

Turn it to the ON position

The carbon brush is worn

Replace the carbon brush

The power outlet contact is
poor

Adjust the power outlet

The rated speed is not
being reached

Adjust it according to the
requirements

AVR is damaged

Replace the AVR