Check safety interlock system, Check for loose hardware, Service air cleaner – Exmark Metro 00 & Higher User Manual

Page 21: Maintenance

Advertising
background image

Maintenance

Figure 9

1.

Rod

4.

Mower deck

2.

Spring

5.

Discharge deflector
bracket

3.

Discharge deflector

6.

Assembled view

3. Hook the bent end of the rod around the front

discharge deflector bracket to retain it from
sliding out. Place the leg of the spring with the
loop in the notch in the discharge deflector to
hold the discharge deflector in the down position
(see Figure 9).

Important: The discharge deflector must be
spring loaded in the down position. Lift the
deflector up to test that it snaps to the full
down position.

Check Safety Interlock
System

Service Interval: Before each use or daily

1. For your safety, your Exmark mower is equipped

with Operator Presence Controls, referred to as
(OPC). When either the PTO is engaged, or the
transmission shifter lever is not in neutral and the
operator removes both hands from the handles,
the mower engine must stop.

2. To determine if the OPC is in operating condition,

clear area of bystanders. Run the engine at
one-third throttle, then with the drive levers and
neutral lock latches in the “park brake” position,

shift the transmission into gear and release the
OPC levers–the engine must stop.

3. Again, run the engine at on-third throttle, move

the transmission shifter lever to neutral, engage
the PTO and release the OPC levers–the engine
must stop
.

Note: If machine does not pass any of these tests,
do not operate. Contact your authorized EXMARK
SERVICE DEALER.

Important: It is essential that operator safety
mechanisms be connected and in proper
operating condition prior to use for mowing.

Check for Loose Hardware

Service Interval: Before each use or daily

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Visually inspect machine for any loose hardware

or any other possible problem. Tighten hardware
or correct the problem before operating.

Service Air Cleaner

Service Interval: Every 25 hours—Service

the foam element. (May
need more often under
severe conditions. See
the Engine Owner’s
manual for additional
information.)

Every 100 hours—Service
the paper element. (May
need more often under
severe conditions. See the
Engine Owner’s manual
for additional information.)

Every 200 hours/Yearly
(whichever comes
first)—Replace the paper
element.

1. Stop engine, wait for all moving parts to stop, and

remove key or spark plug wire(s). Engage parking
brake.

2. See the Engine Owner’s Manual for maintenance

instructions.