Essick Air 4D7 800 User Manual

Page 4

Advertising
background image

4

Fan

Speed

Humidity

Control

Power

CAUTION:

When filling, be careful not to pressurize the bottle by overfilling it. Bottle

damage can result from this, and will not drain properly.
NOTE:

On initial fill up, it will take approximately 20 minutes for the reservoir to fill because

the dry wick has to absorb water. Subsequent fillings will take approximately 12 minutes,
since the wick is already saturated.
10. After the filling process is complete, place the chassis/power pack unit into the cabinet,

so it fits without tipping or rocking.

11. Insert the water bottles into the humidifier, placing them with the valve cap end down, so

that the groove in the water bottle faces the inside.

12. Replace the water bottle cover.

CONTROLS AND OPERATION

1. Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier

should not be near any heat registers. Place the unit at least FOUR inches away from
any walls. Unrestricted airflow into the unit will result in the best efficiency and
performance.

2. The digital controller has a display that provides information on the status of the unit.

Depending on which function is being accessed, it displays relative humidity, fan speed, set
humidity and indicates when the unit is out of water.

FAN SPEED

3. Press the power button and select fan speed: F1

through F9 proceeding from low to high speed.

NOTE:

When excessive condensation exists, a lower

speed setting is recommended.

HUMIDITY CONTROL

NOTE:

Both models have an automatic humidistat that

cycles the humidifier on and off as required to maintain
the selected setting.
4. At initial startup the relative humidity of the room will

be displayed.

5. Each successive push of the Humidity Control Button

will increase the setting in 5% increments. At 65% set
point, the unit will operate continuously.

6. One bottle is designed to empty first. The control

display will indicate each bottle empties with a flashing “F”. When the unit is
completely out of water, the motor will shut off.

7. This humidifier has a check filter reminder timed to appear after 720 hours of operation.

When the Check Filter (CF) message is displayed, disconnect the power cord and check the
condition of the filter. The CF function is reset after plugging the unit back in.

OPTIONAL AIRCARE® FILTER

The optional Aircare® filter is an excellent means of cleaning the air while using your
humidifier. The first stage of the air filter is a high-efficiency, electro-statically charged filter
media which traps dust, pollen, and airborne pollutants. The second stage is an activated
carbon media which absorbs odors from cooking, pets, or tobacco smoke.

Advertising