NOTE:
See venting chart for maximum and minimum vertical / horizontal venting configurations.

LOCATING GAS FIREPLACE

This appliance must be installed in any location that is free of plumbing, electrical wiring and
heating or air conditioning ducts. Select a location that is accessible for venting.
See ALLOWABLE TERMINATION LOCATIONS listed in this manual.

The fireplace may be

installed in any location that maintains proper clearances to combustibles, air conditioning ducts, electrical
wiring and plumbing. Select a location that is accessible for venting See section Allowable Termination
Locations listed in this manual. When the appliance is installed directly on carpeting, vinyl tile or other
combustible materials, other than wood flooring, the appliance must be installed on metal or wood panel
extending the full width and depth of the appliance.

VENT TERMINATION LOCATIONS

ALLOWABLE TERMINATION LOCATIONS and establish a suitable vent termination location.

1. In heavy snowfall areas make sure the vent termination is located where it can not be

blocked by snowfall and / or snow from snow-removal equipment.

2. Locate the vent termination away from plants, bushes or any other object near the vent

termination that will interfere with or obstruct the airflow around it.

3. DO NOT recess vent termination into walls, sidings or planters.
4. Vent terminations located below 7ft (2.13 M) from grade level or anywhere that it can be a

burn hazard to the public, such as patios and balconies, must be protected with an approved
termination cage. If using Archgard Venting System, order Part # C-1.