Atlantic Water Gardens AF1000 User Manual

Page 2

Advertising
background image

Atlantic’s Auto Fill Kit is designed to maintain the correct level of water in your

fountain basin, water garden, pond-free waterfall or other type of water

storage unit.

Labeled drill points have been provided for the proper Auto Fill location on

all Atlantic products (see the products’ installation manuals for drill point

specifications). If you are using any non-Atlantic product, the Auto Fill must be

positioned in an area free of obstructions so the float can travel up and down.

The center point of the Auto Fill should be located 1 ½” to 2” above the

normal operating water level.

Once you have determined the location of the Auto Fill, drill a

7

/

8

” hole using a

spade bit or hole saw. Insert the Auto Fill, making sure the gasket is on the

water side of the unit, and the plastic retaining nut is on the outside. Thread

the retaining nut onto the Auto Fill Valve, being careful not to over-tighten.

The Auto Fill Kit includes fittings for connection to a garden hose, ½” irrigation

line, and ½” Sch 40 PVC. Wrap the ½” male threads on the Auto Fill with thread

sealant and install the fitting of your choice. Once water is supplied to the Auto

Fill it will maintain the set water level by automatically adding water when the

level drops. This level can be adjusted by loosening the wing nut and raising

and lowering the height of the Auto Fill float.

Flow Rate: 0.5 to 1.5 gpm / Inlet Pressure: 80 psi max

AUTO-FILL

VALVE

WATER LEVEL

GASKET

RETAINING

NUT

OUTLET

FITTING

”-2”

WING NUT

Advertising