Warranty, Warranty claims – Atlantic Water Gardens TA1800 User Manual

Page 5

Advertising
background image

5

Diaphragm replacement
Rubber diaphragms are a wearable part that will need servicing over time. Moisture, heat
and dust will all shorten the life of the diaphragms. Please follow the following steps when
installing replacement diaphragms.

• Remove the top cover housing for the air pump. Loosen the air chamber screws (1)

and remove the outer air chamber (2).

• Loosen the diaphragm nut (3) and remove the diaphragm depressor (4), electrostatic

membrane (5) and the damaged diaphragm (6).

• Install the new diaphragm ensuring that the rubber tabs align properly with the notches

on the inner air chamber.

• Once the diaphragm is seated properly, assemble the components by following the

previous steps in reverse order.

6

5

4

3

2

1

Warranty

All Typhoon Air Pumps carry a one year limited warranty. This limited warranty is extended
solely to the original purchaser commencing from the date of original purchase receipt.
The following apply:

• Manufacturer will replace parts found to be defective including pump body, housing,

electric cord, swing arm and internal moving parts.

• Air filter, flapper valves and diaphragms are wearable parts and not covered by

this warranty.

• A cut or altered power cord voids this warranty.

• A misused or abused air pump voids this warranty.

Warranty Claims

In case of warranty claims, the air pump should be returned to place of purchase
accompanied by original receipt.

Advertising