2 installation – Eneo EDMC-3221B/E User Manual

Page 19

Advertising
background image

4

2.2 Installation

You need one optional mount kit of the wall mount and the ceiling mount to install.

The wall or ceiling mount must be attached to a structural object such as hard wood, concrete
that will support the weight of the mount and dome camera.

The use of a solid backboard is recommended when attaching to gypsum walls.

1. Remove the Protection pad and the tape from attached the dome camera.

2. Attach the mounting base to wall using the supplied M8 tapping screw and plastic bushing.

(Ceiling using the supplied M6 tapping screw and bushing)

3. Wind the both thread of the pipe end with Teflon tape about 20 times for sealing. Then use a

silicone rubber sealant to seal the area where the wall (ceiling) mount and the pipe meet.

4. Place a bead of silicone sealant around the wall and ceiling mount mounting flange, press it

to the surface and line up the flange hole with drilled holes.

5. Refer to the Appendix B and C.

CAUTION 1: A silicone rubber sealant must be applied to seal the housing to secure

waterproofing.

CAUTION 2: When installing, a bracket must be applied.

CAUTION 3: Please reset the camera after 30 ~ 60 minutes when installing it in situations

colder than -10°C.

Advertising