Over-the-range microwave, Electrolux major appliances, n.a – Electrolux E30MH65GSS User Manual

Page 2

Advertising
background image

Over-the-Range Microwave

E30MH65GSS designer series

High standards of quality at Electrolux Home Products, Inc. mean we are

constantly working to improve our products. We reserve the right to change

specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

250 Bobby Jones Expressway

Augusta, GA 30907

1-877-4electrolux (1-877-435-3287)

electroluxicon.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxicon.ca

E30MH65GSS 12/08

© 2008 Electrolux Home Products, Inc.

Printed in the U.S.A.

30" Over-the-Range Microwave Specifications

Product Weight – 75 Lbs.

Voltage Rating – 120V / 60 Hz / 20 Amp

Connected Load (kW Rating) @ 120 Volts = 1.6 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)

Amps @ 120 Volts = 14.5 Amps

Always consult local and /or national electric codes.

Grounded outlet should be located in cabinet above, with hole in base
to route power cord. Carefully follow top template instructions for power
cord clearance when installing beneath smooth, flat cabinets.

Microwave’s ventilation system is convertible, designed for two
types of exhaust – outside, using either vertical or horizontal ducting;
or recirculating, requiring no ducting.

For safe and proper installation, microwave MUST be mounted to
BOTH a top cabinet AND a wall, and connected to at least one wall stud.
Can NOT be installed in island or peninsula cabinet arrangements.

Cabinet bottom MUST be level to insure proper installation.

Cabinet MUST be capable of supporting a total load of 110 lbs.

Filler blocks recommended for installation when cabinet front hangs
below recessed bottom shelf.

Minimum distance of 33" required from cooking surface to bottom
edge of top cabinet.

Minimum distance of 69" required from floor to top of microwave.

Opening between cabinets MUST be 30" wide and free of obstructions.

Can only be installed over ranges or cooktops with 33" maximum width.

Allow 25-1/2" minimum clearance for 90° door swing.

Ducted Option Specifications

For outside ventilation only.

Exhaust duct adapter supplied assembled for outside ventilation,
designed to mate with standard 3-1/4" x 10" rectangular duct. If round
duct required, rectangular-to-round transition adapter will be needed
with no less than 6" diameter.

For most efficient airflow exhaust, use a straight run or as few elbows
as possible with maximum duct length of 3-1/4" x 10" rectangular
or 6" diameter round duct, not to exceed 140 equivalent feet.

For horizontal installation, be sure to allow enough space between wall
studs to accommodate exhaust.

Refer to web for detailed duct preparation instructions.

Ductless (Recirculated) Option Specifications

If ducting to outside is not an option, ventilation system can be converted
to ductless to recirculate air inside.

Refer to web for detailed convertible ventilation installation instructions.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxicon.com for detailed instructions.

5" min.

Backsplash

Rear Wall

16

1

/

2

"

min.

30" min.

69" min.

from floor

to top of

microwave

Bottom edge of
cabinet MUST be
33" min. from
cooking surface

Cabinet MUST
be capable of
supporting a total
load of 110 lbs.

12"

min.

33"

min.

Microwave MUST
be mounted to
BOTH a top cabinet
AND a wall*

Locate 120V/60Hz grounded outlet inside upper cabinet

*Can NOT be installed

in island or peninsula
cabinet arrangements

30" min.

33" max.

16

3

/

8

"

29

7

/

8

"

14

3

/

8

"

Blower plate allows for vertical
or horizontal ducting

Power cord location
(right top rear)

16

7

/

8

"

1

/

2

" lower

extrusion

Allow at least 25

1

/

2

" clearance

for door depth when open

16

1

/

8

"