Grass Valley 2042EDA User Manual

Page 13

Advertising
background image

2042EDA Instruction Manual

7

Power Up

A red FAULT LED indicates an error situation and, when noted with
the other indicator LEDs, can indicate a specific problem area.

Table 1

describes signal output and LED indications for the various input/ref-
erence combinations.

Table 2

provides the possible input and output conditions that result

from different input signals and conditions.

Table 1. Indicator LEDs and Conditions Indicated

LED

Indication

Condition

Off Normal

operation

FAULT (red)

On continuously

Module has detected internal fault

Long flash

No input signal on input 1 or input 2

COMM (yellow)

Off

No activity on frame communication bus

Long flash

Location Command received by the module from a remote control system

Short flash

Activity present on the frame communication bus

CONF (yellow)

Off

Module is in normal operating mode

On continuously

Module is initializing, changing operating modes or updating firmware

PWR (green)

Off

No power to module or module’s DC/DC converter failed

On continuously

Normal operation, module is powered

SIG 1 PRES

(green)

Off

Indicates input 1 signal carrier missing or over EQ range

On

Indicates input 1 signal carrier present

SIG 2 PRES

(green)

Off

Indicates input 2 signal carrier missing or over EQ range

On

Indicates input 2 signal carrier present

SIG (rear view)

(green)

Off

Indicates both input 1 and 2 signal carriers missing

On continuously

Indicates both input 1 and 2 signal carriers present

Long Flash

Indicates input 1 missing, input 2 present

Short Flash

Indicates input 1 present, input 2 missing

Table 2. Input and Output Conditions

Input Condition

Output Condition

Serial Digital Component (SDI)

Serial Digital Component (SDI)

HD Digital Component (SDI)

HD Digital Component (SDI)

Other carrier (SMPTE 310M, DVB-ASI)

Other carrier (SMPTE 310M, DVB-ASI)

No input signal

Muted

Cable exceeding 200 – 300 meters

Muted

Advertising