Grass Valley Acappella Quick Start User Manual

Acappella quick start guide, Connect video reference, Connect power cords

Advertising
background image

Acappella

Quick Start

Guide

Acappella Router

Power

License

For all physical configurations

install Acappella in rack

1

Copyright © Grass Valley

071-8364-02 October 2005

1

16

15

2

14

13

12

11

3

10

9

4

16

15

5

14

13

6

12

11

7

8

7

8

6

5

9

4

3

10

2

1

1

16

15

2

14

13

12

11

3

10

9

4

16

15

5

14

13

6

12

11

7

8

7

8

6

5

9

4

3

10

2

1

V

I

D

E

O

A

U

D

I

O

INPUTS

OUTPUTS

ENET

REF

LOOP

J2

J1

SERIAL

Reference Loop

75 ohm Terminator

Reference

Loop

Connect Video Reference

3

Video Reference Specifications, see Table 1

Connect Power Cords

1

16

15

2

14

13

12

11

3

10

9

4

16

15

5

14

13

6

12

11

7

8

7

8

6

5

9

4

3

10

2

1

1

16

15

2

14

13

12

11

3

10

9

4

16

15

5

14

13

6

12

11

7

8

7

8

6

5

9

4

3

10

2

1

V

I

D

E

O

A

U

D

I

O

INPUTS

OUTPUTS

ENET

REF

LOOP

J2

J1

SERIAL

Redundant

Power Supply

Power Supply

Plug into power

to activate unit

Redundant PS

PAL

Color Black

NTSC

Color Black

Switching

middle of line 10

Switching

middle of line 6

Adjustable up to +/- 30.5us

720p/59.94 & 720p/60
720p/50
1080i/59.94 & 1080i/60
1080i/50
1080p/24 & 1080fs/48

Adjustable from -15 lines

up to +16 lines

TLS

Tri-Level-Sync

Switching

middle of line 7

All Input signals and the Video Reference signal need to be in time with each other.

Table 1. Video Reference Specifications

Adjustable up to +/- 10.3us
Adjustable up to +/- 12.7us
Adjustable up to +/- 14.2us
Adjustable up to +/- 17.1us
Adjustable up to +/- 18.0us

Adjustable up to +/- 31.1us

Reference

Type *

Default

Horizontal Offset

(0 midpoint)

Vertical Offset

(0 midpoint)

*

Instruction

Manual

System

Software

Create Network

2

Acappella

Remote Panel

Ethernet Switch

Remote Panel and Switch

Acappella

Crossover Cable

PC

PC

Acappella

Remote Panel

Ethernet Switch

PC

Remote panel, Switch and PC

If Installing Router Only (no remote panels or PC) proceed to STEP 3

Acappella

Ethernet Switch

PC

PC and Switch

Acappella Router IP Address:

192.168.0.40

Acappella

Remote Panel

Crossover Cable

Remote Panel

Remote Panel IP Address:

192.168.0.41

Create closed networks between Acappella Routers,

Remote Panels, and PCs using Ethernet cables and/or

switches. A closed network is one that is kept separate

from other Local Area Networks and the Internet.

Use patch cables if you are using switches between the

routers, panels, and PCs.

It is also possible to use a crossover cable to connect an

Acappella Router directly to either a Remote Panel or a PC;

this option is only practical in very small systems.

One of the five networks shown in step 2 should work for

your facility.

Closed Networks and Acappella Router Systems

Before you begin,

unpack and identify:

Plug into power

to activate unit

Plug into power

to activate unit

Depth

Width

Height

Weight

Voltage Input

Power Consumption

392 mm

15.43 in.

483 mm

19 in.

44 mm

1.75 in.

4.89 kg.

10.78 lbs.

100-240 V AC 50-60 Hz

<40 W

_

Cords

External Power Supply

(Analog Routers)

shown with Remote Panel mounted above

Router

Depth

Width

Height

Weight

Voltage Input

Power Consumption

106 mm

4.18 in.

483 mm

19 in.

44 mm

1.75 in.

1.04 kg.

2.3 lbs.

100-240 V AC 50-60 Hz

<25 W

_

Remote Panel

Remote

Panel

Digital

Router

Analog

Router

1

16

15

2

14

13

12

11

3

10

9

4

16

15

5

14

13

6

12

11

7

8

7

8

6

5

9

4

3

10

2

1

V

I

D

E

O

ENET

REF

LOOP

J2

J1

SERIAL

4

Advertising