electrolux

connecting to the electricity supply

Connecting to the electricity supply

Warning: This appliance must be

earthed. Do not earth this

appliance to gas supply piping.

Connect to 230 - 240V AC supply

only.

Connection to the electricity supply

must be carried out by a qualified

electrician/competent person.

The electrical connection should be

made using a double pole isolating

switch (cooker socket) with at least

3mm contact separation in all poles.

The cable must have conductors of

sufficiently high cross-sectional area

to prevent overheating and

deterioration.

The recommended cross-section

area is six square millimetres

(6.00mm

2

).

The cable should be routed away

from potentially hot areas marked

by X.

Note: House circuit

Earth leakage / continuity tests must be

carried out before the appliance is

connected to the mains supply and re-

checked after fitting.