Configuring Cascade Rooms

In a cascade room, each cascaded display is assigned heads from the other multiviewers,
configured as layers, by setting the display’s Layer 2 head and Layer 3 head properties to
match the actual head order in your physical configuration.

To configure a cascade room:

1 In XEdit, while connected to the multiviewer that will output directly to the monitor

wall (i.e. the multiviewer whose HDMI outputs are connected to the display monitors),
open the room you wish to configure.

2 Click a first head. In the Properties pane, its name appears in the Output head box.

• In the case of a cascade with three multiviewers, select the first multiviewer (i.e. the

one farthest from the monitor wall) from the Layer 3 head (for cascade
configuration)
list:

Note:

Each member of a cluster has its own database where both common

information about the cluster and information local to the individual cluster
member are stored. Room and layout definitions are automatically
replicated to all cluster members, whereas the configuration for devices
connected to a specific system is only stored in this system’s database.

Note:

If the room does not exist yet, create it by adding the appropriate

number of displays, and then assign heads from the current multiviewer to
the displays in the usual fashion.