1-3

Editor Port Jumpers

Editor Port Jumpers

Jumper settings on the Control Processor module must be set as follows for proper
operation of the EDITOR port:

Model 3000

For the Model 3000, the EDITOR port jumpers are located on the Control
Processor module (068906) between the M/E 2 Processor mezzanine board
(068916) and the Serial Communications mezzanine board (068918). See Figure 1-
1. Jumper J71 sets the communication standar
d (RS-232 or RS-422); Jumper J70 sets
the EDITOR port termination (IN or OUT).

Communication Standard

For

RS-422

, set the two jumpers of J71 to the

DIFF

position (RS-422) as shown

in Figure 1-1. This connects pins 1 and 3 together and pins 2 and 4 together.

For

RS-232

, set the two jumpers of J71 to the

RS232

position. This connects pins

3 and 5 together and pins 4 and 6 together.

Termination

Set the two jumpers of J70 to either the

IN

(terminated) position or the

OUT

(not

terminated) position, depending on the requirements of your system.

If J71 is set for RS-232, Jumper J70 has no effect.

Figure 1-1. EDITOR Port Jumper Settings on Model 3000

(shown set for RS422, terminated)

M/E 2 Processor

Mezzanine Board

(068916)

Serial Communication

Mezzanine Board

(068918)

J70

J71

DIFF

RS232

EDITOR

IN

TERM

OUT

Control

Processor

Module

(068906)

rear

edge

connector

0350-11

Advertising
This manual is related to the following products: