Conversion from Natural to LPG Gas

IMPORTANT

The replacement/conversion of the gas hob should
only be undertaken by a CORGI registered
engineer.

It is important to note that this model is designed for
use with natural gas but can be converted for use with
butane or propane gas providing the correct injectors
are fitted. The gas rate is adjusted to suit.

Method

Ensure that the gas taps are in the 'OFF' position

Isolate the hob from the electricity supply

Remove all pan supports, burner caps, rings, crowns
and control knobs.

With the aid of a 7mm box spanner the burner
injectors can then be unscrewed and replaced by the
appropriate LPG injectors.

TO ADJUST THE GAS RATE

With the aid of a thin bladed screwdriver undo the by
pass screw about 1/4 of a turn (45

°

). Upon

completion stick the replacement rating plate near the
gas supply pipe.

Replacement of gas oven
burner nozzle

To replace the gas oven nozzle, follow this procedure:

a) remove the bottom of the oven;
b) undo screw 1 and take the oven burner out;
c) with a socket spanner 7 unscrew and remove the

nozzle, situated in the bottom of the oven, and replace
it with the proper one (see Table on page 20);

d) reassemble the burner following the same procedure

backwards.