Grass Valley Trinix Back-Up Power Supplies Apr 13 2010 User Manual
Page 36
Advertising
36
Trinix — Back-Up Power Supplies Installation Manual
Section 5 — Installation
Figure 2.
DC IN -
DC IN +
PS B
PS A
(1)
(2)
(3)
(4)
(5)
8443
07
Power Connections Showing Reference Numbers Used for this Document
c.
Remove the “DC IN +” and “DC IN -” screws (2), (3), (4), and (5).
d.
Locate the DC power ground stud (1). Use a nut driver to remove
one nut (only) and one washer (only) from the stud.
e.
Connect the supplied external power supply cables as shown in
Figure 3.
DC IN -
DC IN +
PS B
PS A
(1)
(2)
(3)
(4)
(5)
DV-33128/256 External Power Supply Wiring (Partially Complete)