Electrolux Blast Chiller/Freezer 10 GN2/1 User Manual

Page 2

Advertising
background image

Electrolux Blast Freezers

Blast Chiller/ Freezer - 56 kg 10 GN2/1

Internet: http://www.electrolux.com/foodservice

HDBA040

2011-06-10

Subject to change without notice

SLIDE-IN RACK SUPP. BC+BCF 56KG 10 GN2/1

880075

PRINTER HACCP BASIC VERS-REF.ELECR.CONTR

881532

PLASTIFIED GRILL RILSAN GN 2/1

881030

PLASTIC COATED GRID-600X400 MM

880864

KIT TO CONVERT TO 10X2/1 ROLL-IN RACK

922202

KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW

880183

80 MM PITCH SIDE HANGERS FOR 10X2/1 OVEN

922117

60 MM PITCH SIDE HANGERS FOR 10X2/1 OVEN

922123

4 WHEELS FOR BLAST CHILLERS

881097

3-POINT-SENSOR PROBE-BL.C/FREEZERS LW

880212

ACCESSORIES

1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW

1

INCLUDED ACCESSORIES

Power supply - V, phases, Hz

400 V, 3N, 50

Net weight - kg.

235

installed-electric

2.88

Power - kW

at evaporation temperature - °C

-30

Refrigerant power

Refrigeration power - W

2540

Refrigerant quantity - g.

3170

Refrigerant type

R404a

N° defrost in 24 hrs.

3/30'

Compressor power - HP

3

Max load capacity - trays h 65 mm - n°

6

Trays type

GN 2/1; 600x800

Door hinges

Right Side

height

1640

depth/with open doors

1010, 1755

width

1000

External dimensions - mm

Cooling unit

Built-In

Gross capacity (D.I.N. 8952) - l.

560

UK Guide lines - chilling / freezing

64, 56

NF Regulations - chilling / freezing

43.2, 43.2

Productivity per cycle - kg.

Power supply

Electric

TECHNICAL DATA

RBC102

726046

CONSTRUCTION

Internal and external finishing in 304

AISI stainless steel and backpanel in
galvanized steel.

High density polyurethane

insulation, 60 mm tickness, HCFC
free.

Environmentally friendly: R404a as

refrigerant fluid.

Developed and produced in ISO

9001 and ISO 14001 certified factory.

Inner cell with fully rounded corners.

Door equipped with removable

magnetic gasket with hygienic design.

Motors and fan waterproof

protected IP23.

Evaporator with antirust protection.

Ventilator (fan) swinging hinged

panel for access to the evaporator for
cleaning.

Automatic heated door frame.

Thermostatic expansion valve to

optimize the cooling unit efficiency.

Adjustable feet 150 mm high.

Stand alone printer as accessory.

PC connection on request, gate RS

485.
  
INSTALLATION

No water connections required.

Waste water can be plumbed into

drain, but can also be collected in an
optional waste container.

Advertising