Page 16

14008-0-0403

Figures 15 and 18 show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner
flame meet. Figures 16 and 19 show an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple.
This will cause the thermocouple to cool. When the thermocouple
cools, the heater will shut down.

VFSR PILOT

Correct appearance of pilot flame.

Figure 15

Incorrect appearance of pilot flame.

Figure 16

If pilot flame pattern is incorrect, as shown in Figure 16

See Troubleshooting, page 19.

Cleaning and Maintenance/Pilot

Oxygen Depletion Sensor Pilot (Figure 17 )
When the pilot has a large yellow tip flame, clean the Oxygen
Depletion Sensor as follows:

1. Clean the ODS pilot by loosening nut B from the pilot

tubing. When this procedure is required, grasp nut A with
an open end wrench.

2. Blow air pressure through the holes indicated by the arrows.

This will blow out foreign materials such as dust, lint and
spider webs. Tighten nut B also by grasping nut A.

Figure 17

VFSV PILOT

Correct Pilot Flame Pattern

Figure 18

Incorrect Pilot Flame Pattern

Figure 19

If pilot flame pattern is incorrect, as shown in Figure 19

See Troubleshooting, page 19.

PILOT FLAME CHARACTERISTICS

Advertising