"CAUTION"

REMOVE ALL POWER BEFORE INSTALLING OR SERVICING THE UNIT

"CAUTION"

THESE INSTRUCTION ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF

ELECTRICAL SHOCK, DO NOT PERFORM ANY INSTALLATION OR SERVICING OTHER THAN THAT

CONTAINED IN THE OWNERS MANUAL UNLESS YOU ARE QUALIFIED TO DO SO.

“ATTENTION”

THIS DEVICE IS TO BE INSTALLED BY DESIGN INTO A WALL WITH AN OUTLET BOX. FOR PROPER FIT,

A 3-GANG OUTLET BOX IS REQUIRED WITH THE MINIMUM SIZE OF 67.3 CU. IN.

“CAUTION”

THE INSULATING BARRIER PROTECTING PS220 COMPONENTS MUST BE USED WHEN INSTALLING
THE PS220. PLACE THE OUTLET WITH THE INSULATING BARRIER INTO THE OUTLET BOX AND
SCREW THE COVER PLATE AND THE INSULATION BARRIER TO THE OUTLET BOX BEFORE APPLYING
POWER TO THE UNIT.

One of the two options must be used in order for the outlet to operate!

1. Connect a SPST / NO / Latching switch to terminals 1 & 2. Closed contact turns outlets on.
Open contact turns outlets off.

2. Connect the output from any ETA sequencing unit to the input terminals 4 & 5.

ADDITIONAL CONNECTIONS should be made at this time. These connections may include the LED indicator, input
and/or output for daisy chaining.

FINAL CONNECTION: Connect the PS220’s flying wire leads to the wires inside the outlet box.
Green is Ground, Black is Hot, and White is Neutral. Minimum 12 gauge wire.

REMOTE LED INDICATOR: This can be used with remote switch as a remote unit activity indicator. A flashing LED

indicates the unit is actively sequencing. When the LED is on constant the unit is completely “ON” or “OFF.”
To use this feature the (-) negative short lead of the LEDs is connected to terminal 2, and the (+) positive long
lead of the LED is connected to terminal 3.

Thank you for choosing
ETA Systems Power Distribution

Drawing upon our 25 years of solving high-amperage
lighting needs and listening to customers’ concerns,
we have developed a most extensive line of Audio
Conditioned Power Distribution. As the problems
inherent with AC power increase, you will find ETA
providing solutions.

Telephone or e-mail us requesting a Full Line Brochure

All designs and specifications are subject to change without notice.
Copyright © 2003 ETA Systems.

11/03 6MAN-034

A Creative Light & Sound Company

1532 Enterprise Parkway • Twinsburg, Ohio 44087 USA
330-425-3388 • 800-321-6699 • Fax: 330-425-9700
http://www.etasys.com E-mail [email protected]

SYSTEMS

TM

©

SEQUENCING

SYSTEM ON

OFF

ON

KL3RR

KEYLOCK

POWER DISTRIBUTION

ETA SYSTEMS

A Creative Light And Sound Company

KL3R

KL3RR

1-Gang Profile

Standard 19” Rack-Mounted Version

Advertising