Cycle run, Please note while programming – HEIDENHAIN TNC 620 (81760x-02) Cycle programming User Manual

Page 332

Advertising
background image

Touch Probe Cycles: Automatic Datum Setting

14.3 DATUM RIDGE CENTER (Cycle 409, DIN/ISO: G409, software option

17)

14

332

TNC 620 | User's Manual Cycle Programming | 2/2015

14.3

DATUM RIDGE CENTER (Cycle 409,
DIN/ISO: G409, software option 17)

Cycle run

Touch Probe Cycle 409 finds the center of a ridge and defines its
center as datum. If desired, the TNC can also enter the coordinates
into a datum table or the preset table.

1 Following the positioning logic, the TNC positions the touch

probe at rapid traverse (value from

FMAX column) (see

"Executing touch probe cycles", page 298) to touch point

1

. The

TNC calculates the touch points from the data in the cycle and
the safety clearance from the

SET_UP column of the touch

probe table.

2 Then the touch probe moves to the entered measuring height

and runs the first probing process at the probing feed rate
(column

F

).

3 Then the touch probe moves at clearance height to the next

touch point

2

and probes the second touch point.

4 Finally the TNC returns the touch probe to the clearance height

and processes the determined datum depending on the cycle
parameters Q303 and Q305 (see "Characteristics common to all
touch probe cycles for datum setting", page 326) and sa
ves the
actual values in the Q parameters listed below.

5 If desired, the TNC subsequently measures the datum in the

touch probe axis in a separate probing.

Parameter number

Meaning

Q166

Actual value of measured ridge width

Q157

Actual value of the centerline

Please note while programming:

Danger of collision!

To prevent a collision between touch probe and
workpiece, enter a

high

estimate for the ridge width.

Before a cycle definition you must have programmed
a tool call to define the touch probe axis.

If you set a datum (Q303 = 0) with the touch probe
cycle and also use probe in TS axis (Q381 = 1), then
no coordinate transformation must be active.

Advertising