Model ei261enrc co alarm, Technical specification, System wiring – Ei Electronics Carbon Mo-noxide Alarm Ei261ENRC User Manual

Page 2

Advertising
background image

Shannon Free Zone, Shannon, Co. Clare, Ireland.

Ph.

+353 61 471277

Fx.

+353 61 471053

Email.

[email protected]

Web:

www.eielectronics.com

E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice

.

Ei261ENRC DataSht RevA


Technical Specification

Sensor

Electrochemical sensor


Sensitivity:

Meets BS EN 50291:2001

Button Test:

Checks the electronics and horn


Fast CO Test Mode:

Alarm sounds and red indicator
flashes as soon as CO is detected

the rate of flash indicating the CO
level


Memory Feature

A

fter the unit has been in alarm, the red

indicator will flash every 40 seconds at a
rate indicating the CO level previously
detected. Pressing the “Test/Hush”
button will also cause the red indicator
to flash at a rate specific to the
previously sensed CO level.

Automatic Self-Test:

Horn beeps and amber fault light
flashes every 40 seconds if a sensor
fault is found

Supply Voltage:

230V AC, 50 Hz

Battery back up:

Rechargeable Lithium cells

Dimensions:

126 x 150 x 42 mm

Weight:

300g



Model

Ei261ENRC CO Alarm

Power-On Indicator:

Continuous green LED


Alarm:

Electronic Piezoelectric horn


Alarm Sound Output:

85dB(A) (minimum) at 3m


Alarm Status:

Red LED flashes and horn sounds


Normal Operating
Temperature Range:

-10

o

to +40

o

C


Humidity Range:

15% to 95% Relative Humidity

Interconnect:

Up to 12 interconnected
- Ei261ENRC/261DENRC CO alarm

-

Ei161RC/164RC/166RC smoke or

heat alarms

- Ei128RBU relay base

Use with optional control (see below)


Optional Controls:

-

Ei1529RC Control Switch

-

MCP401RC Manual Call Point


Fixing:

Easi-Fit mounting base


Plastic material:

UL94VO flame retardant


Guarantee:

5 year (limited)


Approvals:

Kitemarked to BSEN 50291:2001,
(License no. KM86596) and CE
certified

Specifications are subject to change

System Wiring

Wiring for Interconnected Alarms with optional Remote System Control Switch & Manual Call Point





Ensure correct wiring of the alarms and switches as mixing Live and Neutral will blow / damage interconnected units.




Advertising