Installation, Venting arrangements - vertical terminations – Excalibur electronic P95-LP3 User Manual

Page 18

Advertising
background image

Excalibur

®

P95-3 Zero Clearance Direct Vent Gas Fireplace

18

INSTALLATION

• Vent must be supported at offsets.
• Firestops are required at each fl oor level and whenever passing through a wall.
• Maintain clearances to combustibles.

Note: Must use optional fl ue adapter when using Simpson Dura-Vent pipe (Part # 770-994).

VENTING ARRANGEMENTS - VERTICAL TERMINATIONS

SIMPSON DURA-VENT DIRECT VENT GS SYSTEM

(Propane & Natural Gas)

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90

o

elbow, with

Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas.