Removing a detected energy meter from the PV system
If only one energy meter is detected by the inverter, this will be added to the PV system
automatically. Removal via the menu System Configuration is not possible in this case. To
remove the energy meter from the PV system, proceed as follows:

• In the parameter group PV system communication > Measured values > Meter on

Speedwire set the parameter Serial Number to any number (e.g. 1) (see Section 9.14
"Changing Operating Parameters", page 46)
. In this way, instead of the energy meter
detected, the PV system will add a fictitious energy meter to which the inverter can not
establish communication.

Procedure:

1. Call up the inverter user interface (see Section 8.1, page 34).
2. Log in as Installer.
3. On the right-hand side of the menu bar, select the menu User Settings (see Section 8.2

"Design of the Inverter User Interface", page 37).

4. In the subsequent context menu, select [Start the installation assistant].
5. Select [Save and next] until you arrive in the menu Meter configuration.
6. Add or replace the desired energy meter.

9.13 Configuring Feed-In Management

If required by the grid operator, the inverter can provide grid management services. You can
configure these via the inverter feed-in management. Coordinate the configuration of the feed-in
management with your grid operator beforehand.

Procedure:

1. Call up the inverter user interface (see Section 8.1, page 34).
2. Log in as Installer.
3. On the right-hand side of the menu bar, select the menu User Settings (see Section 8.2

"Design of the Inverter User Interface", page 37).

4. In the subsequent context menu, select [Start the installation assistant].
5. Select [Save and next] until you arrive in the menu Feed-in management.
6. Configure the feed-in management as desired.

9.14 Changing Operating Parameters

The operating parameters of the inverter are set to certain values by default. You can change the
operating parameters to optimize the performance of the inverter.