Fuel conversion, Maintenance and service – Enviro ENVIRO User Manual

Page 11

Advertising
background image

11

Maintenance And Service

F

UEL

C

ONVERSION

:

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing.

Warning: This conversion kit shall be installed by a qualified service agency in accordance

with the manufacturer’s instructions and all applicable codes and requirements of the

authority having jurisdiction. If the information in these instructions is not followed

exactly, a fire, explosion or production of carbon monoxide may result causing property

damage, personal injury or loss of life. The qualified service agency is responsible for

the proper installation of this kit. The installation is not proper or complete until the

operation of the converted appliance is checked as specified in the manufacturer’s

instructions supplied with the kit.

Figure 10: Removing the orifice.

Kit Parts List:

Orifice (NG - PO512-37 DMS or LP - PO512-1/16” DMS)

Installation instruction sheet
Carefully inspect all parts supplied with this conversion kit. If

any parts have been damaged or are missing, contact your

dealer, distributor or courier company to have them replaced

before starting this installation.
Conversion Kit Installation:
1. Turn control knob on the gas valve to the “OFF” position

and shut the gas supply off at the shut-off valve upstream

of the unit. CAUTION: The gas supply must be shut off

prior to disconnecting the electrical power and before

proceeding with the conversion. Allow the valve and unit

to cool down to room temperature.

2. Remove the glass door as shown in the M

AINTENANCE

AND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

.

3. Carefully remove the log set.
4. Slide the burner back just far enough so the front edge of

the burner does not catch on the front lip of the firebox.

Lift the front of the burner up and out of the firebox. See

M

AINTENANCE

AND

S

ERVICE

- B

URNER

R

EMOVAL

& I

NSTALLATION

.

5. Convert the burner orifice:

a) Remove the main burner orifice with a 3⁄8” socket

(refer to Figure 10).

b) Install the alternate orifice from the kit.

6. Convert the pilot injector:

a) Loosen the pilot stem a half turn using a

7

/

16

” wrench

(refer to Figure 11).

b) Slide the tab to the other side of the pilot stem (refer

to Figures 12 & 13).

c) Tighten the pilot stem.

Figure 11: Turning Pilot Stem.

Figure 12: NG & LP Gas Positions on Pilot.

Advertising