SB25_30-BA-BEN115030 | IMEN-SB25_30 | Version 3.0

EN

PV Inverter

SUNNY BOY 2500/3000

User Manual

ES

Symbols on the Inverter

Operation display.

Ground fault or varistor defective.

Inform your installer.

An error has occurred. Inform your installer immediately.

You can operate the display by tapping it (see section entitled "Operation").

Symbols on the Type Label

Beware of hazardous voltage.

The inverter operates at high voltages. All electrical work

on the inverter must be carried out by electrically qualified persons

only.

Beware of hot surface.

The inverter can become hot during operation. Avoid contact during operation.

Observe enclosed documentation.

The inverter must not be disposed of together with the household waste.

Further disposal information can be found in the enclosed installation manual.
CE marking. The inverter complies with the requirements of the applicable EC

directives.
RAL quality mark for solar products. The inverter complies with the requirements of

the German Institute for Quality Assurance and Labeling.
Direct current (DC)
Alternating current (AC)
The inverter is protected against dust intrusion and water jets from any angle.

The inverter has a transformer.

AC

Abbreviation for "Alternating Current".
DC

Abbreviation for "Direct Current".
Derating

Controlled reduction of power due to excessive temperature or the grid operator's specifications, e.g.

using the Power Reducer Box.
Electronic Solar Switch (ESS)

The Electronic Solar Switch is part of the inverter DC disconnection unit. The

Electronic Solar Switch must be securely inserted into the bottom of the inverter and must

only be removed by electrically qualified persons.
MPP (Maximum Power Point)

Operating point of the inverter depending on current/voltage of the PV array. The actual position of

the MPP changes constantly, depending on the level of radiation and cell temperature.
PV

Abbreviation for photovoltaics.
Varistor

The varistors protect the electronics in the inverter from atmospherically coupled energy peaks, such as

those that can occur when lightning strikes nearby.

ExPLANATION Of SYMBOLS

GLOSSArY

CONTACT

If you have technical problems, first contact your installer. The following information is required in

order to provide you with the necessary assistance:
• Inverter device type

• Inverter serial number

• Type and number of PV modules connected

• Blink code or display message of the inverter

• Optional equipment (e.g. communication devices)

SMA Solar Technology AG

Sonnenallee 1

34266 Niestetal, Germany

www.SMA.de

SMA Service Line
Inverters

+49 561 9522 1499

Communication: +49 561 9522 2499

Fax:

+49 561 9522 4699

E-Mail:

[email protected]

Installer contact

Visual Inspection

Check the inverter and lines for any visual signs of external damage. Contact your installer if you find

any damage. Do not perform any repair work yourself.

Maintenance and Cleaning

If the inverter is dirty, clean the enclosure lid, the display, and the LEDs using only clean water and a

cloth.

Ask your installer to check for correct inverter operation at regular intervals.