SMA STP 8000TL-10 User Manual

Pv inverter sunny tripower, Contact

Advertising
background image

STP8-17TL-BA-en-40 | IMEN-STP10-17TL | Version 4.0

EN

PV Inverter

SUNNY TRIPOWER

User Manual

8000TL/10000TL/12000TL/15000TL/17000TL

Symbols on the Inverter

Operation display

Bluetooth

®

Wireless Technology.

Bluetooth communication active.*

An error has occurred. Inform your installer immediately.

There are special requirements for earthing.

Symbols on the Type Label

Beware of dangerous voltage.

The inverter operates at high voltages. Any electrical work on the inverter must be

carried out by electrically qualified persons only.
Beware of hot surface.

The inverter can become hot during operation. Avoid contact during operation.

Observe enclosed documentation.

The inverter must not be disposed of together with household waste.

Further disposal information can be found in the enclosed installation manual.
CE marking: The inverter complies with the requirements of the applicable EC

directives.
RAL quality mark for solar products: The inverter complies with the requirements of

the German Institute for Quality Assurance and Labelling.
Device class label: The inverter is equipped with a wireless component that complies

with the harmonised standards.

Certified safety: The inverter complies with the requirements of the European

Equipment and Product Safety Act.
Australian mark of conformity
Korean mark of conformity
Direct current (DC)
Three-phase alternating current (AC) with neutral conductor
The inverter is protected against dust intrusion and water jets from any angle.

The inverter does not have a transformer.

* The Bluetooth

®

word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any

use of these marks by SMA Solar Technology AG is under licence.

AC

Abbreviation for "Alternating Current".

Bluetooth

Bluetooth is a radio technology that allows the inverter and other communication products to

communicate with each other. Bluetooth communication does not require line of sight between the

devices.

DC

Abbreviation for "Direct Current".

Electronic Solar Switch (ESS)

The Electronic Solar Switch is part of the DC disconnection unit of the inverter. The Electronic Solar Switch

must be securely inserted into the bottom of the inverter and may only be removed by a skilled person.

Energy

Energy is measured in Wh (watt hours), kWh (kilowatt hours) or MWh (megawatt hours). The energy is

the power calculated over time. If, for example, your inverter operates at a constant power of 3,000 W

for half an hour and then at a constant power of 2,000 W for another half an hour, it has fed 2,500 Wh

of energy into the power distribution grid within that hour.

Power

Power is measured in W (watts), kW (kilowatts) or MW (megawatts). Power is an instantaneous value.

It displays the power your inverter is currently feeding into the power distribution grid.

PV

Abbreviation for photovoltaics.

Visual Inspection

Check the inverter and cables for any visual signs of external damage. Contact your installer if you find

any damage. Do not perform any repair work yourself.
Maintenance and Cleaning

If the inverter is dirty and the visibility of the operating data and operating states of the inverter is

limited, clean the enclosure lid, the display and the LEDs with a damp cloth. Do not use any corrosive

substances (e.g. solvents or abrasives) for cleaning.

Ask your installer to check for correct inverter operation at regular intervals.

ExPLANATION Of SYMbOLS

VISUAL INSPECTION, MAINTENANCE AND CLEANINg

gLOSSARY

If you have technical problems, first contact your installer. The following information is required in

order to provide you with the necessary assistance:
• Inverter device type

• Inverter serial number

• Type and number of PV modules connected

• Event number or display message on the inverter

• Optional equipment (e.g. communication products)

SMA Solar Technology Ag

Sonnenallee 1

34266 Niestetal, Germany

www.SMA.de

SMA Service Line

Inverters:

+49 561 9522 1499

Communication: +49 561 9522 2499

Fax:

+49 561 9522 4699

E-Mail:

[email protected]