14 technical data, 1 sunny tripower 8000tl – SMA STP 8000TL-10 User Manual
Page 95
SMA Solar Technology AG
14 Technical Data
Installation Manual
STP8-17TL-IA-en-31
95
14 Technical Data
14.1 Sunny Tripower 8000TL
DC Input
* The maximum open-circuit voltage which can occur at a cell temperature of − 10°C must not exceed the maximum input voltage.
** To be observed in the event of short-circuit of the electronic string fuse.
Maximum DC power at cos φ = 1
8,200 W
Maximum input voltage*
1,000 V
MPP voltage range
320 V … 800 V
Rated input voltage
600 V
Minimum input voltage
150 V
Initial input voltage
188 V
Maximum input current, input A
22.0 A
Maximum input current, input B
11.0 A
Maximum input current per string input A**
33.0 A
Maximum input current per string input B**
12.5 A
Number of independent MPP inputs
2
Strings per MPP input, input A
4
Strings per MPP input, input B
1