DWG. NO. 02Y00025-0415
SHEET NO. 1 OF 5
R E L . 1 0 / 2 8 / 9 6

( m - df )

For GPD 333
and GPD 5 0 3

Adjustable Frequency Drives

CHANGE RECORD

DATA

DISPLAY

JOG

COPY
MODE

RESET

F / R

VRFY

DRIVE

PRGM

SWITCH

ENTER

READ

RUN

COPY

STOP

REMOTE

COPY UNIT
JVOP-105

SEQ REF

DRIVE FWD REV

COPY UNIT

MODEL NO. DS596

Before installing this option, a TECHNICALLY QUALIFIED INDIVIDUAL, who is familiar with this type of
equipment and hazards involved, should READ this ENTIRE INSTRUCTION SHEET.

INTRODUCTION

When installed, the Copy Unit (DS596) is used to read out constant settings from a drive and to copy them into
other drives easily from a remote location, up to 9.8 ft (3 m) from the drive. The Copy Unit is similar to Digital
Operator, Model No. DS393.

NOTE: Constants cannot be read from and copied to different types of drives.

EXAMPLE: GPD 333 ———> GPD 503.

IMPORTANT

The appropriate length Remote Operator Cable for connecting the Copy Unit, and the Remote
Interface Panel, Model DS390 (for the GPD 333), must be ordered separately.