Yaskawa SigmaTrac XY Adapter Plate User Manual

Sigmatrac xy adapter plate

Advertising
background image

1.2. Secure XY adapter plate to carriage with 8 - M6x18 socket head cap screws.

Recommend applying Loctite threadlocking adhesive to the threads. Tighten to the

recommended tightening torque, 8.1 N-m.

SigmaTrac XY Adapter Plate

Part Numbers: SGTA-CC1, SGTA-CC2

1. SGTA-CC1: For mounting a SGT1F31 or SGT1F41 series SigmaTrac on a SGT1F31

or SGT1F41 series SigmaTrac, follow the instructions outlined below.

Kit includes the following parts:

1 - XY adapter plate with dowel pins

14 - M6x18 mm socket head cap screws

Doc#: IG.SigmaTracSGT.01 Yaskawa Electric America, Inc.2010 www.yaskawa.com April 1, 2010 1/4

1.1. Align and insert dowel pins on XY adapter plate with center dowel

holes on SGT1F31 / SGT1F41 carriage.

Advertising