5.3 Alarms

56

* Reset at S

ON signal ON.

# LED will blink at warning before alarm.

Encoder

Communication Error

Communication error between encoder and

digital torque amplifier.

Communication between the encoder and

digital torque amplifier failed three times in

succession.

Runaway Detection

Motor runaway

*

.

Encoder Failure

Checksum error in EEPROM within

encoder

Error in the number of pulses in encoder

rotation

Error in EEPROM within encoder

Error in communication data between

encoder and digital torque amplifier.

Main Circuit Power

Error

DC input with AC input settings for main

circuit power or AC input with DC input

settings.

Main circuit power was frequently tuned

ON/OFF

*

.

Combination Error

Improper combination of motor and digital

torque amplifier capacities.

Improper motor combination.

Digital Torque

Amplifier Fault

Failure of A/D converter used in command

input

Servo amplifier system error

Linear Motor Scale

Polarity Error

Polarity setting of the linear motor scale A,

B-phases is reversed.

Alarm