Appendix B PRECAUTIONS ON VS-656DC5 APPLICATION

E-59

„

Power Supply Capacity Selection

Use a power supply with a capacity larger than the VS-656DC5 rated input capacity. If a
power supply with a capacity smaller than the VS-656DC5 rated input capacity is used, an
operation error may occur. When selecting a power supply, contact your Yaskawa represen-
tative.

Use the following formula to obtain the VS-656DC5 rated input capacity.

„

Interlocking with Inverters

It is necessary to interlock between the VS-656DC5 and the Inverter to stop the Inverter by
using the VS-656DC5 fault signal. To restart the operation after a memontary power loss at
the Inverter side, the timing for reactivation must be assured.

The “MC Operating (MCON)” signal that the VS-656DC5 outputs from the control terminal
is used to assure the timing. When the “MC Operating (MCON)” signal is “open,” use the
Inverter external baseblock input to make a sequence to shut OFF the Inverter output.

[Typical Interlock]

• When reactivation after momentary power loss is not performed (Coasting to a stop by

momentary power loss detection)

Insert the VS-656DC5 “MC Operating (MCON)” output to the Inverter “External Fault”
input.

The Inverter “External Fault” input is NC contact input. To prevent external fault oper-
ation at power supply ON, select “External fault accepted only during RUN.”

• When reactivation after momentary power loss is performed as system

Insert the VS-656DC5 “MC Operating (MCON)” output to the Inverter “External BB”
input.

Select reactivation after momentary power loss at the Inverter side. Then select the
coasting lead-in mode or speed search mode.

Select NC contact input for the Inverter “External BB” input.

„

Precautions on Application of Peripheral Devices

When a noise filter is attached on the VS-656DC5 power supply side, use a noise filter of the
reactor type (without a capacitor) such as finemet zero-phase reactor, and attach it behind the
MCCB at the power supply side. Do not use a capacitor-built-in type noise filter since the
harmonic components may overheat or damage the capacitor.

S

conv

3

×

I

AC_rate

×

V

in

÷

1000

[I

AC_rate

: VS-656DC5 rated input current (A), V

in

: Power supply line voltage (V)]