2.1 Installation Environment and Applicable Standards

2-3

2

Installation

2.1.2 SERVOPACK Installation Environment

„

Surrounding air temperature: 0 to 55

°C

„

Ambient humidity: 90% RH or less (with no condensation)

„

Altitude: 1,000 m or less

„

Vibration resistance: 4.9 m/s

2

„

Shock resistance: 19.6 m/s

2

„

Installation Precautions

• Mounting in a Control Panel

To prevent the temperature around the SERVOPACK from exceeding 55

°C, take into

account the size of the control panel, the layout of the SERVOPACK, and the cooling
method. For details, refer to 2.3 SERVOPACK Installation.

• Mounting Near a Heating Unit

To prevent the temperature around the SERVOPACK from exceeding 55

°C, suppress

radiant heat from the heating unit and temperature rise due to convection.

• Mounting Near a Vibration Source

To prevent vibration from being transmitted to the SERVOPACK, install a vibration
isolator underneath the SERVOPACK.

• Mounting to a Location Exposed to Corrosive Gas

Take measures to prevent exposure to corrosive gas. Corrosive gases will not imme-
diately affect the SERVOPACK, but will eventually cause electronic components and
contactor-related devices to malfunction.

• Other Locations

Do not mount the SERVOPACK in locations subject to high temperatures, high
humidity, dripping water, cutting oil, dust, iron filings, or radiation.

<Note>

When storing the SERVOPACK with the power OFF, store it in an environment with
the following temperature and humidity:

• -20 to +85

°C, 90% RH or less. (with no condensation)