Troubleshooting – Irritrol Total Control-R Series User Manual

Page 27

Advertising
background image

25

Error

Solution

All valves

1. Verify program: station time, watering start

will not

times, watering days schedule, current time,

turn on

current day, water budget and rain delay.

automatically

2. Check valve common wire for proper

connection.

3. Check for a shorted station; refer to
4. “How the electronic circuit breaker works”

on page 5.

5. Ensure rain sensor (if installed) is properly

connected and functioning properly. If rain
sensor is not installed, ensure the

SENSOR SWITCH

is in

BYPASS

position.

6. Check fuse, replace if necessary. See p. 27.

Cannot

1. Disconnect power to controller for

program

1 minute. Reconnect power and reprogram.

2. Install fresh 9-volt alkaline battery.
3. Verify that all 16 start times are not in

use by other programs.

Controller

1. Verify watering start times, current time

skips a cycle

and watering days schedule.

No display

1. Check power source for tripped circuit

breaker.

2. If program module has been removed, this

is a normal battery-saving feature. Turn dial
to any position to reactivate display.

3. Disconnect power to controller for 1 min.

Reconnect power and reprogram.

4. Replace battery
5. Check fuse, replace if necessary. See p. 27.

Troubleshooting

TROUBLESHOOTING