ntroductIon

Contained in this manual are installation instructions,

maintenance procedures and parts information for the

1-inch and 2-inch Mark D and DA Series Globe and

Angle Style Control Valves. Refer to the appropriate

manuals for instructions for the accompanying actua-

tor and additional accessories.

Trained or experienced personnel should carry out

operation and installation of all pressure equipment.

If you have any questions regarding the equipment,

contact your Jordan Valve representative.

I

nstallatIon

Warning

Jordan Valve recommends the use of protective
clothing, gloves and eyewear when performing any
installation or maintenance.

Installation of the valve assembly under conditions
which exceed the limits outlined in this manual
or on the nameplate may result in personal injury.
Overpressure may cause sudden release of pro-
cess pressure or bursting of assembly parts.

The valve configuration and construction materials
of each assembly are specified during ordering to
meet specific pressure, temperature, pressure drop
and controlled fluid conditions. Do not operate any
part of the assembly outside of those conditions
without first contacting Jordan Valve.

1.

Before installing the valve, inspect the valve

body cavity for foreign material.

2.

Remove all foreign materials such as scale or

welding slag from all pipelines.

3.

Unless limited by existing seismic condi-

tions, the control valve assembly may be

installed in any position. The normal

method is with the actuator vertical above

the valve.

4.

Install the valve so the process flow co-

incides with direction shown by the arrow

on the valve body.

5.

Use accepted piping and welding

practices when installing the valve in the

line. For flanged valve bodies, use

suitable gaskets between the body

flanges and pipeline flanges.

Note

Post-welding heat treatment may be required
on some valve body materials. Avoid damage
to internal elastomeric, plastic and metal parts
by removing all trim. For more information,
contact your Jordan Valve representative.

6.

For screwed end connections, apply pipe

compound to pipeline threads.

7.

Install a conventional 3-valve bypass

around the body to allow for continuous

operation during maintenance

and inspection.

8.

If your actuator and valve body were

shipped separately, refer to the

proper Product Manual for actuator

mounting procedures.

Warning

Packing leakage could result in personal injury.
Valve packing is tightened prior to shipping
but may require readjustment to meet specific
service conditions.

Warning: Jordan Valve Control Valves must only be used, installed and repaired in accordance with these Installa-
tion & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event
of leakage or other malfunction, call a qualified service person; continued operation may cause system failure or
a general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disassem-
bling a valve, be sure to release all spring tension.

3170 Wasson Road • Cincinnati, OH 45209
Phone 513.533.5600 • Fax 513.871.0105 (f)
[email protected] • www.jordanvalve.com

I & M Mark D and DA Series

Installation & Maintenance Instructions for the

Mark D & DA Globe and Angle Style Control

Valves