Jordan Valve Mark EW Series Globe Style Панель управления User Manual

I & m mark ew series, Nstallation, Ntroduction

Advertising
background image

I

nstallatIon

Exceeding the recommended pressure and tempera-

ture limits indicated on the nameplates of your Jordan

valve control valve, can result in personal injury and

property damage. Jordan Valve recommends the

installation of a relief valve to protect against overpres-

sure situations.

The Mark EW Series valve bodies are designed to

meet specific conditions for fluid control, temperature,

pressure and pressure drop. The limiting factor on

these valves can be the body/trim material combina-

tions. Do not install these valves in any other applica-

tions without first consulting with your Jordan Valve

representative.

During installation, Jordan Valve recommends the use

of a sling to protect the painted surfaces of the valve.

Position the sling to avoid damage to tubing and ac-

cessories.

1.

Inspect the valves for shipping damage and

foreign debris while uncrating.

2.

Ensure the pipeline is free of welding slag,

chips and other debris by blowing out the line

before installation.

3.

Position the valve so the arrow on the valve

body is in the same direction as the pipeline

flow.

4.

Specific orientation of the control valve as-

sembly is flexible, unless limited by the

seismic criteria. Normal positioning

is with the actuator vertical above the valve

body. Should a different position be required,

be aware that the result may be uneven valve

plug and cage wear, and inefficient opera-

tion of the control valve system. Also,

be aware that the actuator may need addi-

tional support. Consult Jordan Valve for further

information on orientation.

5.

Always employ proper piping and welding

practices when installing the valve in the line.

If welding is required, internal elastomeric

parts may remain in place. If the valve

has buttwelding ends and composition

trim, remove the composition trim prior

to welding into the line.

6.

For flanged bodies, install an appropriate gas

ket between the pipeline and valve body flang

es.

7.

With leak-off bonnet construction, remove the

pipe plugs (Figure 1, Keys 14 and 23)

to connect the leak-off piping. To avoid an

interruption of service during inspection or

maintenance, install a three-valve bypass

around the control valve assembly.

8.

Most Jordan valves are shipped with

the actuator already installed according to

customer specifications. If your actuator has

been shipped separately, refer to the appropri-

ate mounting instructions in the actuator

manual.

I

ntroductIon

Contained in this manual are installation instructions,

maintenance procedures and parts information for the

Mark EW Series Valve Body designs EWD, EWS and

EWT. Refer to the appropriate manuals for instructions

for the accompanying actuator and additional acces-

sories.

Trained or experienced personnel should carry out

operation and installation of all pressure equipment.

If you have any questions regarding the equipment,

contact your Jordan Valve representative.

3170 Wasson Road • Cincinnati, OH 45209
Phone 513.533.5600 • Fax 513.871.0105 (f)
[email protected] • www.jordanvalve.com

I & M Mark EW Series

Installation & Maintenance Instructions for the

Mark EW Series Globe Style Control Valve

Warning: Jordan Valve Control Valves must only be used, installed and repaired in accordance with these Installa-
tion & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event
of leakage or other malfunction, call a qualified service person; continued operation may cause system failure or
a general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disassem-
bling a valve, be sure to release all spring tension.

Advertising