Jordan Valve Mark HPX and HPAX Series Globe & Angle Style Панель управления User Manual

I & m mark hpx and hpax series, Nstallation, Ntroduction

Advertising
background image

I

nstallatIon

Exceeding the recommended pressure and tem-

perature limits from Table 1, or those indicated on the

nameplates of your Jordan Valve Controls valve, can

result in personal injury and property damage. Jordan

Valve recommends the installation of a relief valve to

protect against overpressure situations.

Mark HPX900 and 1500 Series, HPX2D and HPX5T are

designed to meet specific conditions for fluid control,

temperature, pressure and pressure drop. The limiting

factor on these valves can be the body/trim material

combinations. Do not install these valves in any other

applications without first consulting with your Jordan

Valve representative.

1.

Inspect the valves for shipping damage and

foreign debris while uncrating.

2.

Ensure the pipeline is free of welding slag,

chips and other debris by blowing out the

line before installation.

3.

Position the valve on the line so the flow

direction indicator corresponds to the di-

rection of the flow of the pipeline.

4.

Jordan Valve recommends the installation

of a standard three-valve maintenance by

pass. This will allow isolation of

the control valve without shutting down

the pipeline system.

5.

Install approved gaskets between the

valve body and the pipeline flanges.

6.

If the actuator has been shipped sepa-

rately, refer to the mounting procedure in

the applicable instruction manual.

7.

If the valve body arrives without packing

installed in the packing box, it will be

necessary to install the packing before

putting the valve into service. To

complete these procedures, follow the

instructions under “packing maintenance”

in this manual.

8.

Note: It may be necessary to adjust the

packing to prevent leakage. Prior

to shipping the packing was tightened,

and may require some adjustment

for specific conditions.

I

ntroductIon

Contained in this manual are installation instructions,

maintenance and parts information for the 2 through

6-inch Mark HPX2D, HPX5T, HPAX2, HPAX5, ASME

Class 900 and 1500 ratings. 2 inch ASME Class 2500

also included. Refer to the appropriate manuals for

instructions for the accompanying actuator, positioner

and additional accessories.

Only trained or experienced personnel should carry

out the operation and installation of all pressure

equipment. If you have any questions regarding the

equipment, contact your Jordan Valve representative.

A serial number identifies each Series H valve and

is stamped on the valve body. Please reference this

number when communicating with your Jordan Valve

representative.

3170 Wasson Road • Cincinnati, OH 45209
Phone 513.533.5600 • Fax 513.871.0105 (f)
[email protected] • www.jordanvalve.com

I & M Mark HPX and HPAX Series

Installation & Maintenance Instructions for the

Mark HPX and Mark HPAX Globe and Angle Style

Control Valves

Warning: Jordan Valve Control Valves must only be used, installed and repaired in accordance with these Installa-
tion & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event
of leakage or other malfunction, call a qualified service person; continued operation may cause system failure or
a general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disassem-
bling a valve, be sure to release all spring tension.