Mechanical compliance

Vibration:

General Vibration (operating): Refer to MIL-STD-810G,

Method 514.6, Procedure I (Transportation), Category

4 – Common carrier (US highway truck vibration

exposure)
General Vibration (non-operating): Refer to MIL-STD-

810G, Method 514.6, Procedure I (Transportation),

Category 24 – General minimal integrity

Shock:

Operating (Functional Test for Ground Equipment):

Refer to MIL-STD-810G, Method 516.6, Procedure I,

40g, 11ms
B. Non-Operating (Crash Hazard Shock Test for Ground

Equipment): Refer to MIL-STD-810G, Method 516.6,

Procedure V, 75g, 11ms

Electrical transient conduction along supply lines only

(12V/24V)

Revision History

Revision

Revision Date Changes

1.1

20130806

DVI-D, maximum

resolution changes

from 75 to 60Hz

VGA, maximum reso-

lution changes from

60 to 75Hz

1.2

20130924

Change HDDSL1

jumper settings

1.3

20140701

Change the default

BIOS values for DIO

Advertising