TROUBLESHOOTING

WARNING: If you smell gas:

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover,
cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion
air and create odors and possible discoloration of walls and ceilings.

OBSERVED SYMPTOM

POSSIBLE CAUSE

REMEDY

TROUBLESHOOTING CON’T

Burner plaque(s) does not glow
[Infrared Only]

Slight smoke or odor during
initial operation

Heater produces a whistling
noise when burner is lit

Burner backfiring during
operation

1. Burner orifice is clogged or damaged

2. Burner damaged
3. Gas regulator defective
1. Plaque damaged
2. Control knob set between locked posi-

tions.

3. Inlet gas pressure is too low
1. Residues from manufacturing process

1. Turning control knob to HI position when

burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice.

1. When heated, vapors from furniture

polish, wax, carpet cleaners, etc., turn into
white powder residue

OBSERVED SYMPTOM

POSSIBLE CAUSE

REMEDY

1. Clean burner orifice (see Cleaning and

Maintenance on page 13), or replace
burner orifice

2. Replace burner
3. Replace gas regulator
1. Replace burner
2. Turn control knob until it locks at desired

setting.

3. Replace gas regulator
1. Problem will stop after a few hours of
operation
1. Turn control knob to LO position and let

warm up for a minute.

2. Operate burner until air is removed from

line have gas line checked by local gas
company.

3. Observe minimum installation

clearances(see Figure 4 page6)

4. Clean burner orifice (see Cleaning and

Maintenance on page 13), or replace
burner orifice.

1. Turn heater off when using furniture

polish, wax, carpet cleaner or similar
products.

White powder residue forming
within burner box or on
adjacent walls or furniture

1. Heater burning vapors from paint, hair

spray, glues, etc. See IMPORTANT
statement above

2. Gas leak. See WARNING statement at

top of page.

1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak. See WARNING statement at

top of page

2. Control valve is defective
1. Foreign matter between control valve and

burner

2. Gas leak. See WARNING statement at

top of page

1. Metal expanding while heating or contract-

ing while cooling

1. Not enough combustion/venitlation air

1. Ventilate room. Stop using odor-causing

products while heater is running.

2. Locate and correct all leaks (see Checking

Gas Connections, page 8)

1. Open window and/or door for ventilation
2. Contact local gas company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 13)

1. Locate and correct all leaks (see Checking

Gas Connections, page 8)

2. Replace control valve
1. Take apart gas tubing and remove foreign

matter

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 8)

1. This is common with most heaters. If noise

is excessive, contact qualified service
person

1. Refer to Fresh Air of Combustion and

Ventilation page 3 through 5.

Heater produces unwanted
odors.

Heater shuts off in use (ODS
operates)

Gas odor even when control
knob is in OFF position

Gas odor during combustion

Heater produces a clicking/
ticking noise just after burner
is lit or shut off

Moisture/condensation noticed
on windows

Advertising