Magnum Energy MP-HOOD User Manual

Mp-hood instruction sheet, Mp-hood

Advertising
background image

MP-HOOD Instruction Sheet

Part Number: 64-0047 Rev A

1

Magnum Energy, Inc.

2211 West Casino Rd.

Everett, WA, USA 98204

www.magnumenergy.com

Introduction

The MP-HOOD is designed to prevent objects from falling inside the top vents

of the inverter, which can cause damage inside the inverter. Normally, Magnum

inverters are mounted horizontally without any vents facing the top or bot-

tom. However, in installations where these inverters are mounted on a vertical

surface (DC side down) - such as on a MMP or MP enclosure - the MP-HOOD

must be mounted above the inverter to meet UL regulatory requirements.

Installation

Info:

The MP-HOOD does not mount to the inverter chassis, it

must be mounted against the wall.

The mounting slots on the

MP-HOOD will accept up to a maximum 1/4 inch screw/bolt.

CAUTION:

The MP-HOOD is not to be used as a drip shield

to

prevent water drip from entering the inverter.

Refer to Figure 1 to install the MP-HOOD; ensure the following requirements:
1. The bottom edge of the MP-HOOD must be mounted fl ush against the top

of the Magnum inverter; this is the optimal position for minimizing the risk of

objects falling into the inverter, and at the same time providing the clearance

needed for air fl ow from the top vents of the inverter.
2. Do not place anything on top of the MP-HOOD that might cause it to bend down-

ward; or place anything on the sides to restrict air fl ow through the inverter.

Figure 1, Installing the MP-HOOD

P lace the bottom edge of

the M P -H OOD flush

against the top of the

M agnum Inverter

Place the bottom edge

of the MP-HOOD flush

against the top of the

Magnum inverter.

Using appropriate mounting

hardware (1/4” maximum

diameter screw/bolts),

securely mount the MP-HOOD

above the inverter.

MP-HOOD

MAGNUM

INVERTER

(mounted

vertically)