Me-pt1 instruction sheet, Me-pt1 to me-ags-s operation, Installation/setup – me-ags-s (standalone version) – Magnum Energy Pigtail Adapters ME-PT1 User Manual

Page 2: Installation, Setup

Advertising
background image

ME-PT1 Instruction Sheet

2

© 2014 Magnum Energy, Inc.

Figure 1, ME-PT1 to ME-AGS-N Installation

12-volt

DC supply

fu

s

e

12-volt

DC supply

fu

s

e

ME-AGS-N

External

Maintain Switch

External

Momentary Switch

ME-RC

One time push

(or close): gen runs
for duration of run
time cycle, then stops.

ME-ARC

Press switch:

gen runs for 2
minutes, then stops.

Coleman Air Conditioner Zone Control Box

ON

OFF

ME-ARC

Switch set

to ON: gen runs until
switch set to OFF.
Switch set to OFF:
gen runs for 2 mins.,
then stops.

ME-RC

Switch set to

ON: gen runs until
switch set to OFF.
Switch set to OFF: gen
runs for remaining
duration of run time
cycle, and then stops.

options

PT1-AGS

To Network port on

Magnum inverter

All grounds must be bonded

together to ensure the ME-PT1

works correctly

GEN connection

provides +12VDC

from Zone Control

Box when gen

needs to start.

GEN

connection

GREEN (GND)

WHITE (L2)

BLACK (L1)

ZONE CONTROL BOX

115 VAC IN

9

-P

I

N

P

L

U

G

T

O

U

P

P

E

R

U

N

I

T

FRE EZE ROOM

HE AT
SHED

COOL
SHED

T

O

U

S

E

W

I

T

H

L

O

A

D

S

H

E

D

D

E

V

I

C

E

R

E

M

O

V

E

J

U

M

P

E

R

A

N

D

C

O

N

N

E

C

T

T

O

N

.C

.

C

O

N

T

A

T

C

T

ROOM

SENSOR

F

R

E

E

Z

E

S

E

N

S

O

R

ME-PT1

ME-ARC

A. Using a momentary type switch: Pressing the switch causes the generator
to run for two minutes, and then stop.

B. Using a maintain type switch: If the switch is set to ON, the generator
continues to run until the switch is set to OFF. Once the switch is set to OFF,
the generator will run for two minutes, and then stops.

ME-PT1 Instruction Sheet

© 2014 Magnum Energy, Inc.

3

Installation/Setup – ME-AGS-S (Standalone Version)

The following pertains to the ME-PT1 when connected to the ME-AGS-S
(Standalone Version) controller.

Info: Other than the specifi c installation and setup instructions
listed below, refer to the ME-AGS-S Owner’s Manual (64-0004) for
installation, setup, and operation of the ME-AGS-S.

Installation

To prepare the ME-AGS-S remote switch:

1. Find the temperature sensor behind the remote switch’s front plate. It is a

small reddish looking device close to the metal front plate (see Figure 2).

2. Use a pair of small wire cutters to cut open one side of the temperature

sensor wire (see Figure 3). Ensure the cut ends are not able to touch.

To install the ME-PT1 (refer to the steps below and Figure 4):

1. Plug a 6-conductor phone splitter into the REMOTE (purple) port on the

ME-AGS-S controller.

2. Plug the ME-PT1 adapter into one of the phone splitter’s ports, and

then plug the remote switch—using its communications cable—into the
phone splitter’s other port.

3. Connect the red wire on the ME-PT1 adapter to a +12-volt DC external

switching device (i.e., switch).

Temperature

Sensor

Temperature

Sensor

(cut open)

Figure 2, Locating Sensor

Figure 3, Sensor Cut Open

Setup

1. On the ME-AGS-S, turn the START TEMP F adjustment clockwise to any

temperature position (DO NOT turn counterclockwise to OFF position).

2. Press the remote switch on the ME-AGS-S to the up (ENABLE) position.

ME-PT1 to ME-AGS-S Operation

The type of external switch (i.e., “maintain” or “momentary”) connected to
the ME-PT1 adapter determines how long the generator can run.

A. Using a

momentary type switch:

Pressing the switch causes the generator

to run for the duration of the RUN TIME HOURS period, and then stop.

B. Using a

maintain type switch:

If the switch is set to OFF, the generator

stays off. If the switch is set to ON, the generator runs until the switch is set
to OFF. Once the switch is set to OFF, the generator will not stop until the
current RUN TIME HOURS cycle has been satisfi ed.