10

3.3.2 CLASSIC

300

TROUBLESHOOTING

Error: the amplifier doesn’t start-up Warning: the amplifier keeps functioning Message: operating messages

Display Message

Type

Explanation

Power supply failure!

Error

The power supply has failed. Contact an authorized technician for repair.

Amplifier failure!

Error

The power amplifier has failed. Contact an authorized technician for repair.

Cabinet not connected!

Error (until you connect a
cabinet)

No cabinet is connected to your amplifier.

Cabinet impedance/short!

Error (until you connect correctly
to a suitable cabinet)

The impedance of your cabinet/s is too low, or there is a short circuit. Check your
connection and/or your cabinet/s.

Temp too high!

Error (until the temperature
decreases)

The temperature inside the amplifier has reached an unsafe level.
Make sure the amplifier is properly ventilated.

V(#) tube failure!

Warning

One or more tubes are not working correctly or have failed.
You should have the tube/s replaced by an authorized technician as soon as possible.

Main voltage too low!

Warning

Main power supply voltage is below the nominal value by 10% or more.

Main voltage too high!

Warning

Main power supply voltage is above the nominal value by 10% or more.

Markbass
Classic 300

Message

Startup message

Amp Management System V#.#

Message

Software version. This message appears during startup.

Tube heating

Message

Duration: 32 seconds. This message appears during startup. A progress bar shows the
time remaining until the amp is ready to use.

Long Life – biasing..###

Message

Duration: approximately 10 seconds. This message appears during the power tube biasing
phase, when Long Life mode has been selected.

.

High Fidelity – biasing..###

Message

Duration: approximately 10 seconds. This message appears during the power tube biasing
phase, when High Fidelity mode has been selected.

Ready

Message

This message appears after the biasing phase, when the amplifier is working properly and
ready for use.

Standby

Message

You have selected standby mode. Press standby again when you’re ready to use the amp.

Mute

Message

You have selected mute mode. Use the footswitch to deactivate mute mode when you’re
ready to use the amp.

Advertising