Model ei261denrc co alarm, Technical specification, System wiring – Ei Electronics Carbon Mo-noxide Alarm Ei261DENRC User Manual

Page 2

Advertising
background image

Shannon Free Zone, Shannon, Co. Clare, Ireland.

Ph.

+353 61 471277

Fx.

+353 61 471053

Email.

[email protected]

Web:

www.eielectronics.com

E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice

.

Ei261DENRC DataSht RevA


Model

Ei261DENRC CO Alarm

Technical Specification

Sensor

Electrochemical sensor


Sensitivity:

Meets BS EN 50291:2001

Button Test:

Checks the electronics and horn


Fast CO Test Mode:

Alarm sounds and red indicator
flashes as soon as CO is detected

the rate of flash indicating the CO
level


Memory Feature

When the Test button is pressed the
horn will sound and the digital display
will show the level of CO gas
previously sensed

Automatic Self-Test:

The horn will beep every 40 seconds
and the digital display will show

SF

in

the event of a sensor fault

Supply Voltage:

230V AC, 50 Hz

Battery back up:

Rechargeable Lithium cells

Dimensions:

126 x 150 x 42 mm

Weight:

330g

Specifications are subject to change


Power-On Indicator:

Continuous green LED


Alarm:

Electronic Piezoelectric horn


Alarm Sound Output:

85dB(A) (minimum) at 3m


Alarm Status:

Horn sounds, digital display shows

CO level and red LED flashes


Temperature Range:

-10

o

to +40

o

C


Humidity Range:

15% to 95% Relative Humidity

Interconnect:

Up to 12 of these units can be
interconnected:
- Ei261ENRC/261DENRC CO alarm

-

Ei161RC/164RC/166RC smoke or

heat alarms
- Ei128RBU relay base

Use with optional control (see below)


Optional Controls:

-

Ei1529RC Control Switch

-

MCP401RC Manual Call Point


Fixing:

Easi-Fit mounting base


Plastic material:

UL94VO flame retardant


Guarantee:

5 year (limited)


Approvals:

Kitemarked to BS EN 50291:2001
(License no. KM86596) and CE
certified

System Wiring

Wiring for Interconnected Alarms with optional Remote System Control Switch & Manual Call Point





Ensure correct wiring of the alarms and switches as mixing Live and Neutral will blow / damage interconnected units.




Advertising