Warning, Check exhaust diverter, Caution – Exmark Ultra Vac QDS 00 & Higher User Manual

Page 21: Lubricate grease fittings, Check condition of belt, Maintenance

Advertising
background image

Maintenance

WARNING

Under normal use the cloth mesh will
deteriorate and wear. Objects could exit
through worn cloth mesh at high speeds.
Thrown objects can cause serious injury or
kill you or bystanders.

Check cloth mesh frequently for tears and
holes. Replace worn cloth mesh.

Check Exhaust Diverter

Service Interval: Before each use or daily

CAUTION

The exhaust diverter is hot. Touching a hot
exhaust diverter can cause severe burns.

Allow the exhaust diverter to cool completely
before performing maintenance.

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Inspect and remove debris from the exhaust

diverter daily.

Lubricate Grease Fittings

Note: See chart for service intervals.
1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Lubricate fittings with NGLI grade #2

multi-purpose gun grease.

Refer to the following chart for fitting locations
and lubrication schedule.

Lubrication Chart

Fitting

Locations

Initial

Pumps

Number of

Places

Service

Interval

1.

Idler

Bushings

1–2

1

25 Hours

2. Door
Handle

1–2

1

25 Hours

3.

Lift

Handle Pivot
(LZUVQD11
Only)

1–2

1

Yearly

Check Condition of Belt

Service Interval: Every 50 hours

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Inspect the belt for damage or wear. Replace belt

with one of the following:

Deck

Part No.

48 inch

1-653333

52 inch

1-653438

60 inch

103-0866

72 inch

103-0867

21