Trouble shooting, Replacement parts – Parkside PAS 500 B1 User Manual

Page 12

Advertising
background image

12

GB

Trouble shooting

Problem

Possible cause

Fault correction

Device does not start

Mains voltage is not

present

Check plug socket, cable,

line, plug and fuse, where

appropriate, repair through

electrical specialist

The equipment is not

switched on

Switch on the equipment (see

“switching on/off“)

Safety stop due to missing

or incorrectly inserted

pleated filter ( 13)

Insert the pleated filter correctly

(see “cleaning/maintenance“)

Defective on/off switch

( 6)

Repair through customer

service

Defective motor

Low or lack of suction

Suction hose ( 11)

or suction tube ( 12)

blocked

Remove obstructions and

blockages

The metal container ( 10)

is not closed

Close the metal container

The metal container ( 10)

is full

Empty the metal container (see

“cleaning/maintenance“)

The pleated filter ( 13) is

clogged

Clean or replace the

pleated filter (see “cleaning/

maintenance“)

The air filter ( 17) is

clogged

Clean the air filter (see

“cleaning/maintenance“)

Replacement parts

You can order replacement parts directly via our Service Centre (see addresses

page 69). Please state the appliance type when placing an order.

Item Description ........................................................................... Product No.

13

Pleated filter .............................................................................. 91099216

14

Wire filter basket........................................................................ 91099217

12

Suction tube .............................................................................. 91099242

11

Metal suction hose .................................................................... 91099243

Advertising