Trouble shooting, Gb ie cy – Parkside PNTS 1500 A1 User Manual

Page 12

Advertising
background image

12

GB IE

CY

Trouble shooting

Problem

Possible.cause

Fault.correction

Device does not

start

Mains voltage is not

present

Check plug socket, cable, line,

plug and fuse, where appropriate,

repair through electrical specialist

Defective on/off switch

( 10)

Repair through customer service

Worn carbon brushes
Defective motor

Low or lack of

suction

Hose system ( 18/19)

or jets ( 21-24) blocked

Remove obstructions and blockages

Suction pipes ( 16)

assembled incorrectly

Assemble suction pipes correctly

Collector ( 5) open

Close collector

Collector ( 5) full

Empty collector

Filter ( 11/12/13) full or

clogged

Empty, clean or replace filter