Technical data, Before starting the equipment – Parkside PSE 2800 A1 User Manual

Page 46

Advertising
background image

46

GB/

MT

5. Technical data

Generator: Synchronous

Protection type:

IP23

Continuous rated power P

rated

(S1): 2600

W

Maximum power P

max

(S2 2 min):

2800 W

Rated voltage U

rated

:

2 x 230V~

Rated current I

rated

: 11.3

A

Frequency F

rated

: 50

Hz

Drive engine design:

4-stroke, air-cooled

Displacement: 207.7

cm³

Fuel: Petrol

Tank capacity:

15 l

Engine oil:

approx. 0.6 l (15W40)

Consumption at 2/3 load:

approx. 1.36 l/h

Weight: 42

kg

L

pA

sound pressure level:

76 dB(A)

L

WA

sound power level

96 dB(A)

K uncertainty:

2.07 dB(A)

Power factor cos ϕ:

1

Power class:

G1

Max. temperature:

40°C

Max. altitude (above mean sea level): 1,000 m

Spark plug:

F7 RTC

Operating mode S1 (continuous operation)
The equipment can be continuously operated
with the quoted power output.

Operating mode S2 (temporary operation)
The equipment may be temporarily operated
with the quoted power output (2 min).

6. Before starting the equipment

6.1 Assembly
The installation of the equipment requires two
open-ended wrenches (size 12).

Assemble the foot (16), wheels (14) and
push bar (18) as shown in Figures 6-9.
Assemble all parts before filling in fuel and
oil in order to prevent the fluids from leaking
out.
To mount the wheels, first slide the axle (15)
through the mountings on the bottom of the
generator and fit the wheels (14) as shown
on Figure 7.
When fitting the push bar (18) check that the
angled side (Fig. 9/Item E) is pointing
outwards to ensure that the swing up
function works properly.

6.2 Electrical safety

Electric supply cables and connected
equipment must be in perfect condition.
The generator is to be operated only with
equipment whose voltage specifications
conform to the generator’s output voltage.
Never connect the generator to the power
supply (socket-outlet).
Keep the cable length to the consumer as
short as possible.

6.3 Environmental protection

Dispose of soiled maintenance material and
operating materials at the appropriate
collection point.
Recycle packaging material, metal and
plastics.

6.4 Connecting to earth
The housing must be connected to earth in
order to discharge static electricity. To do this,
connect one end of a cable to the earth
connection on the generator (Fig. 3/Item 4) and
the other end to an external earth.

Anleitung_4152413_LB5:_ 26.10.2011 16:27 Uhr Seite 46

Advertising