Ie gb cy trouble shooting – Parkside PHD 150 A1 User Manual
Page 12
12
IE
GB
CY
Trouble shooting
Problem
Possible cause
Remedy
Washer is not
operating
ON / OFF switch (10) is
turned off
Check ON / OFF switch (10)
Damaged power supply
cable (6)
Check power supply cable (6) for
damage. If necessary have the power
supply cable (6) replaced by a quali-
fied electrician.
Mains fault
Check the electrical system for confor-
mity with the data on the rating plate.
Washer does
not generate
any pressure
Air trapped in the pressure
washer
Turn on the washer with high-pressu-
re hose until bubble-free water flows
out of the high-pressure connection.
Drop in the water mains
pressure
Check the water mains.
Severe pressu-
re fluctuations
High-pressure nozzle (17)
is dirty
Rinse the high-pressure nozzle (17)
with water. If necessary clean the
nozzle hole with a needle.